LK166
Home >> Products >> OMRON >> Power/other peripheral devices >> Power Supply >> Switching power >> S8VM-05012CD Switching Mode Power Supply OMRON S8VM-05012CD

S8VM-05012CD Switching Mode Power Supply OMRON S8VM-05012CD

Brand: OMRON
Name: Switching Mode Power Supply
Model: S8VM-05012CD
Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 50W.
Output voltage: 12V.
Output current: 4.3A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"

Category: incidental cover with under voltage detection function.
Structure: bottom mounting type.
Capacity: 15W.
Output voltage: 24V.
Output current: 0.65A.
Alarm output: -.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device OMRON S8VM-05012CD.
Built in support for determining the abnormal causes of the new under voltage detection function S8VM-05012CD
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage OMRON S8VM-05012CD.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2 OMRON S8VM-05012CD. (except for type 15/30W)
"

Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.090 A; 60 Hz, 0.080 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W S8VM-05012CD OMRON.
Rated rotational speed: 50 Hz, 2200 r/min; 60 Hz, 2500 r/min.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0.7 m3/min.
Maximum static pressure: 50 Hz, 25 S8VM-05012CD OMRON. 0 Pa; 60 Hz, 32.0 Pa.
Noise: 50 Hz, 26 dB; 60 Hz, 29 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 typpe) included in series S8VM-05012CD OMRON S8VM-05012CD.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certiffied safety standards depend on the,
product OMRON S8VM-05012CD. Check the information given for available models of Axial fans and,
the information in Characteristics.


...More relevant models >>>>