Independent type, the function of the built-in controller is not RS-232C, the maximum 256 points.
Name: Clamp Terminal Blocks.
Specifications: Inputs/Outputs;
8 inputs/8 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system OMRON SRM1-C01-V2.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
SRM1-C01-V2
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Outputs; NPN (- common); 16 points.
I/O connections: M3 Screw terminals OMRON SRM1-C01-V2.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply OMRON SRM1-C01-V2.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier. I/O classification: Input and output.
Internal I/O circuit common: PNP (input: – common; output: + common).
I/O points: 32.
I/O connection method: MIL connector.
Rated voltage for communications power supply: 24 VDC.
Rated voltage for I/O power supply: 24 VDC.
Applicable relay: G3DZ-2R6PL.
Subminiature 32-point Remote Terminal with Connectors.
Compact dimensions: 35 × 60 × 80 (W × D × H).
Long-distance and high-speed communications modes available.
Downsizing enabled with 32-point MIL connector for I/O connection.
Unit: Connector model.
I/O classification: Digital output.
Internal I/O common: NPN (- common).
I/O points: 16.
I/O connectionns: Molex connector SRM1-C01-V2.
Power supplyvoltage: 24 VDC.
I/O specification: 0.5 A, DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The ciircuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires SRM1-C01-V2.
DIN track mounting.