Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 3.75 A.
UL Class 2 Output standards: Yes.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
indication monitor.
Status displayed on 3-digit, 7-segment display.
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
Power rating: 25 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 12 V VDC.
Output current: 2.1 A.
Built-in fan: None.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation OMRON S8VS-09024S.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage
S8VS-09024S
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications OMRON S8VS-09024S.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 4 to 10 A OMRON S8VS-09024S.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal S8VS-09024S OMRON.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements S8VS-09024S OMRON.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage S8VS-09024S OMRON.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.155 A; 60 Hz, 0.135 A .
Rated input: 50 Hz, 12 W; 60 Hz, 10 W.
Rated rotational speed: 50 Hz, 2800 r/min; 60 Hz, 3300 r/min.
Maximum flow rate: 50 Hz, 0.80 m3/min; 60 Hz, 0.90 m3/min.
Maximum static pressure: 50 Hz, 42 Pa; 60 Hz, 58 Pa.
Noise: 50 Hz, 37 dB; 60 Hz, 40 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-blladed models,
(28 type) included in series S8VS-09024S.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certiffied safety standards depend on the,
product OMRON S8VS-09024S. Check the information given for available models of Axial fans and,
the information in Characteristics.