LK166
Home >> Products >> OMRON >> Temperature controller >> input device >> Temperature Sensor E52-CA2GVY OMRON E52-CA2GVY

Temperature Sensor E52-CA2GVY OMRON E52-CA2GVY

Brand: OMRON
Name: Temperature Sensor
Model: E52-CA2GVY
Classification: Exclusive Models.
Description: Bayonet spring for molding machines.
Temperature range (See note 3.): 0°C to 350°C.
Element type: K (CA) J (IC).
Conductor type: Grounded type.
Class: 2 (0.75).
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 21.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.

Size: 96 × 96 mm.
Control type: 4-loop control.
Control mode: 4-loop standard control,
2-loop heating and cooling control (See note 2.).
Outputs(control/transfer): 4 (2 pulse + pulse/2current).
Optional functions: Auxiliary outputs (SUB), 10 (See note 1.);
Event inputs, 8; Serial communications, RS-485 OMRON E52-CA2GVY.
A new High-speed, High-precision Digital.
Controller that is Programmable!
Create up to 32 programs with up to 256 segments total E52-CA2GVY
Coordinated operation for up to four channels with one Digital Controller.
0.01°C High resolution for Pt input.
High-speed sampling at 50 ms.
Settings easily made from a computer using the CX-Thermo.
RoHS compliance for world-wide application. The main body: terminal type, temperature input type OMRON E52-CA2GVY.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function OMRON E52-CA2GVY.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade E52-CA2GVY OMRON.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type E52-CA2GVY OMRON.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E52-CA2GVY OMRON. Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Standard control Heating and cooling control.
Outputs(control/transfer): 2 (current + current).
Optional functions: Auxiliary outputs (SUB), 4; Event inputs, 2;
Serial communications, RS-485.

A new High-speed, High-precision Digital E52-CA2GVY.
Controller that is Programmable!
Create up to 32 programs with up to 256 segments total.
Coordinated operation for up to four channels with one Digital Controller.
0.01°C High resolutioon for Pt input OMRON E52-CA2GVY.
High-speed sampling at 50 ms.
Settings easily made from a computer using the CX-Thermo.
RoHS compliance for world-wide application.