LK166
Home >> Products >> OMRON >> Power/other peripheral devices >> Power / equipment protection equipment >> Protective equipment for equipment >> Three-phase Voltage Relay K8AB-PW2 OMRON K8AB-PW2

Three-phase Voltage Relay K8AB-PW2 OMRON K8AB-PW2

Brand: OMRON
Name: Three-phase Voltage Relay
Model: K8AB-PW2
Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
380, 400, 415, 480 VAC, 220, 230, 240, 277 VAC.
Ideal for monitoring 3-phase power supplies.
for industrial facilities and equipment.
Monitor overvoltages and undervoltages for three-phase 3-wire,
or 4-wire power supplies.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Separate outputs possible for overvoltages and undervoltages.
World-wide power specifications supported by one Unit,
(switchable using DIP switch).
Relay status can be monitored using LED indicator.

Control power supply voltage: 200/220 VAC.
Input: DC or AC (selectable); input voltage range: 10 to 300 V: Operating mode,
ON-delay; OFF-delay; Startup lock.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V OMRON K8AB-PW2.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) K8AB-PW2
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection OMRON K8AB-PW2.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Number of inputs: 16.
Number of contacts: 20.
I/O: Inputs.
Mounted Connector model: XG4A-2031 (PLC side), XN2D-4431 (input side).
Cable Connector Model: XG4M-2030-T (PLC side), XN2A-1470 (input side).
Conversion Unit with Industrial OMRON K8AB-PW2.
Standard e-CON Terminal Block.
Connectors.
I/O connectors for easier wiring.
Easy connections via connectors (no special tools required).
Compatible with e-CON connectors from other companies K8AB-PW2 OMRON. Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input K8AB-PW2 OMRON. ).
Power ratings: 15 W.
Output voltage: 5 V.
Output current: 3 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models) K8AB-PW2 OMRON.
Safety standards: UUL 508/60950-1, cUL CSA C22 K8AB-PW2. 2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The inpuut voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply OMRON K8AB-PW2. ).


...More relevant models >>>>