Safety installation number on the controller: up to 2 units (total WSO-GETH00200 and WSO-GCC100202)
Network type: Ethernet (TCP/IP).
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file.
Category: Category 4 (EN/ISO13849-1), class 4 (EN954-1).
Security level: SIL, CL3 SIL3.
Performance level: PLe.
EFI connecting port number: 2.
EFI connection method: spring clip terminal table connection.
Setting interface: RS-232.
Use special setting monitoring tools to configure the configuration directly MITSUBISHI WS0-GETH00200.
Constitute a rich set of components can be easily and quickly set the hardware structure
WS0-GETH00200
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file MITSUBISHI WS0-GETH00200. Category: Category 4 (EN/ISO13849-1), class 4 (EN954-1).
Security level: SIL, CL3 SIL3.
Performance level: PLe.
EFI connecting port number: 0.
EFI connection method: -.
Setting interface: RS-232.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic MITSUBISHI WS0-GETH00200.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file WS0-GETH00200 MITSUBISHI. Transmission speed: 156kbps/625kbps/2.5Mbps/5Mbps/10Mbps (automatic tracking) WS0-GETH00200 MITSUBISHI.
Station No.: 1~64 station.
External connection mode: 2 pieces of spring clip terminal.
Spring clip terminal.
The safety controller can communicate with the master station of the CCLINK system.
The data from the security controller to the master station can be edited by the parameters.
The security controller receives the data from the master station to set the tag name WS0-GETH00200 MITSUBISHI.
Transmission speed according to the auttomatic tracking station, do not need to set the transmission speed WS0-GETH00200.
By using the spring clamping terminal, the wiring time and the maintenance time of the CC-Link cable can be reduced.
No need to re write parameters after rreplacement of the module MITSUBISHI WS0-GETH00200.
The security controller can be set up and connected with the monitoring software.
Confirm the error record that is detected.