Type: cable plug connector.
Contact number: 5.
Ideal choice for connecting sensors.
The connection of the spring clip which is verified by the industry is adopted.
Can be re wiring (maintenance).
Any core wire size between.
(outer diameter: no more than 1.5mm).
A clamp capable of simultaneously connecting 4 lines when a connection is also provided.
UL standard (Document No. E103202) identified as a standard product.
Cable connector with the UL standard certification of products.
Cable: PVC.
Cable core number (core): 3.
Cable outlet direction: L type.
Cable length L:2m.
LED:PNP.
The province, province hours maintenance, use waterproof connector environment and strong tolerance of FA.
Conform to IP67. FA small special connector flame retardant 94V-0.
The connector wiring system, convenient equipment maintenance, reduce equipment downtime OMRON XN2A-1570.
IEC61076-2-101 (IEC60947-5-2)
XN2A-1570
For LED products, can clearly confirm the status of the sensor action.
Accessory: Stand.
This ionizer series is designed to go anywhere.
All models are easily installed on narrow,
workbenches or in high positions where earlier,
models presented installation issues. Time specification: Inverse type OMRON XN2A-1570.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button OMRON XN2A-1570.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
iss indicated from the start of operation XN2A-1570.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions XN2A-1570. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.