No. of cable cores: 4.
Item: Vibration-proof robot cable.
Cable connection direction: Right-angle.
Cable length L: 1 m.
Small Round Water-resistive.
Connectors.
Water-resistive, compact connector meets IP67 requirements.
S8 snap-in models that connect and disconnect with one touch.
Ideal for a wide variety of FA and OA applications.
Connectors on both cable ends require no harness work.
Some new M8 models with 3 or 5 poles.
Capacity: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Maximum cutoff output current (per branch): 3.8 A.
Total output current: 20 A.
Number of output branches: 8 branch outputs.
Communications functions: None.
Parameter settings: Changeable.
A New Type of Power Supply That.
Provides Safety and Maintainability XS3F-M422-401-R OMRON.
240- and 480-W power supplies with and digital circuit,
protectors in a single package
XS3F-M422-401-R
Each branch output tripping current value can be easily,
set at 0.1-A increments.
Startup and shutdown sequence control included.
Various monitor displays and alarms (output voltage,
output current, maintenance forecast monitor,
temperature).
Conforms to UL Class 2 XS3F-M422-401-R OMRON.
Mounts to DIN Rail. Power ratings: 15 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 5 V.
Output current: 2.0 A.
UL Class 2 Output standards: Yes.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that XS3F-M422-401-R OMRON.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Control power supply voltage: 100/110 VDC.
Input: DC or AC (selectable); input voltage range: 10 to 300 V: Operating mode,
ON-delay; OFF-delay; Startup lock.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
AAvailable in 7 supply voltage configurations XS3F-M422-401-R.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection XS3F-M422-401-R.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).