Cable: PVC.
Cable core number: 3.
Cable outlet direction: L type.
Cable length L:5m.
Small round type waterproof connector.
Small waterproof connector can meet the requirement of protection IP67.
Is the ideal choice for a variety of FA and QA applications.
As with connector cable products, so no need for wiring operation.
Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.230 A; 60 Hz, 0.220 A.
Rated input: 50 Hz, 15 W ; 60 Hz, 14 W .
Rated rotational speed: 50 Hz, 2,750 r/min; 60 Hz, 3200 r/min.
Maximum flow rate: 50 Hz, 2.7 m3/min; 60 Hz, 3 OMRON XS3F-M8PVC3A5M. 1 m3/min.
Maximum static pressure: 50 Hz, 93.1 Pa; 60 Hz, 99.0 Pa
XS3F-M8PVC3A5M
Noise: 50 Hz, 42 dB; 60 Hz, 46 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series OMRON XS3F-M8PVC3A5M.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan) OMRON XS3F-M8PVC3A5M.
Capacity: 15W.
Output voltage: 24V.
Output current: 0.65A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Suupport finger touch protection to prevent electric shock XS3F-M8PVC3A5M.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whenn the fan is replaced by the customer XS3F-M8PVC3A5M. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"