No. of poles: 5.
Connection method: Screw-on.
Suitable cable dia: 7 mm (6 to 7).
Core conductor size: 0.18 to 0.75 mm.
Suitable sheath material: PVC, PE, PUR.
Straight Connectors.
Minimum order: 50.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved.
Rated voltage: 100 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 1.1 m3/min; 60 Hz, 1.3 m3/min.
Maximum static pressure: 50 Hz, 67 Pa; 60 Hz, 63 Pa.
Noise: 50 Hz, 45 dB; 60 Hz, 48 dB OMRON XS5G-D5S9.
Weight: Approx. 1150 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting
XS5G-D5S9
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment OMRON XS5G-D5S9.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Connector type: Plug and socket on cable ends.
Cable connection direction: Straight.
Applicable wire diameter: --.
Number of cores: 8.
Cable length: 5 m.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort OMRON XS5G-D5S9.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily beccause operation time,
is indicated from the start of operation XS5G-D5S9.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions XS5G-D5S9. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,