Servo trunk unit.
Product Name: servo relay unit.
Application unit: FQM1-MMA22/MMP22.
Specifications: servo drive G5/G series /SMARTSTEP2.
Axis number: biaxial.
Save the wiring servo drive and position control unit.
Simple wiring on terminal stage.
The connector without soldering, with only a screwdriver can wiring.
Dedicated connection cable between units.
DIN guide rail installation, the rapid installation, screw installation of two methods.
M3.0 thread terminals attached with a special plate signal.
Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.055 A; 60 Hz, 0.048 A .
Rated input: 50 Hz, 5 W ; 60 Hz, 4 W .
Rated rotational speed: 50 Hz, 1900 r/min; 60 Hz, 2100 r/min.
Maximum flow rate: 50 Hz, 0.4 m3/min; 60 Hz, 0 XW2B-80J7-12A OMRON. 5 m3/min.
Maximum static pressure: 50 Hz, 19.5 Pa; 60 Hz, 23.5 Pa.
Noise: 50 Hz, 28 dB; 60 Hz, 30 dB
XW2B-80J7-12A
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series XW2B-80J7-12A OMRON.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Type: Cable with Connectors on Both Ends (RJ45/RJ45).
Category: Cat XW2B-80J7-12A OMRON. 6a .
Cable sheath material: LSZH.
Cable color: Yellow.
Cable length: 2 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks. Control supply voltage: 110/220 VAC; With voltage fluctuation compensation.
Operating current: 2 to 4 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out tthe burned element even if one heater el,
ement among several heater elements has been burned out XW2B-80J7-12A.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with booth single-phase and three-phase heaters XW2B-80J7-12A.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.