LK166
Home >> Products >> OMRON >> Power/other peripheral devices >> Connection / Save wiring equipment >> Connector terminal station conversion unit >> XW2D-40G6-RM Slim Connector-Terminal Block Conversion Units OMRON XW2D-40G6-RM

XW2D-40G6-RM Slim Connector-Terminal Block Conversion Units OMRON XW2D-40G6-RM

Brand: OMRON
Name: Slim Connector-Terminal Block Conversion Units
Model: XW2D-40G6-RM
Mounted Connector: XG4A MIL Connectors.
No. of poles: 40.
Dimension A: 149.
Dimension B: 110.
Mounted Connector model: XG4A-4031.
Cable Connector model: XG4M-4030-T.
New Slim Connector-Terminal Block,
Conversion Units.
Mounting area reduced by 35% (in comparison with,
40-pole XW2B Units) to contribute to downsizing,
control panels and automatic equipment.
Fallout prevention for terminal screws.
Round or forked crimp terminals can be used.
Mount to DIN Track or via screws.
Unique DIN Track lock can maintain open status,
during DIN Track attachment and removal.
Terminal cover can be locked open.
Screw terminals are arranged by color in groups,
of five to simplify counting terminal numbers.

No. of poles: 4.
Suitable cable dia: 6 mm dia. model (5 to 6 mm dia.).
Suitable core size: 0.18 to 0.75mm.
Suitable Sheath material: PVC, PE, PUR.
L-shaped connectors (for DC).
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating OMRON XW2D-40G6-RM .
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime XW2D-40G6-RM
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202 OMRON XW2D-40G6-RM . Measuring voltage: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed OMRON XW2D-40G6-RM .
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply XW2D-40G6-RM OMRON. Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker XW2D-40G6-RM OMRON.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90V (7 shunt).
Time hopping: timing; -0.2-0.4-0.6-0.8-1.0
-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: No, and input common; there, DC operation.
Rating consumption VA: No, 6VA (input side);
Have, 2VA (input side) 10W (control power supply side) XW2D-40G6-RM OMRON.
Control: 1C, 1A AC110V 7.5Acos output with =0.4
(max 250V 825VA AC);
24V 5A L/R=7ms DC (max 125V 50W when DC).
Display: start display (LED display),
Action display (trip) manual reset.
Automatic experiment: -.
Quality: about 2kg.
External: Mount Searl N1.5.
Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work thhrough high reliability semiconductor circuits XW2D-40G6-RM .
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within thhe hidden from the start to the 2S timer, can easily adjust the time OMRON XW2D-40G6-RM .
The control power of the relay is not needed, which avoids the trouble of wiring.


...More relevant models >>>>