Sensor type and connection: 3 line DC (PNP) /2 line 1-4 DC.
Actuator connection: actuator connection 3-4.
Port number: 6.
Cable length: 5m.
Therefore, less artificial.
Wear resistant thin, protection grade can reach IP67.
Proximity sensor and sensor with I/O connector (M12) limit switch.
In addition, due to the increase of the rated current, the ground terminal is increased,
So it can support and connect the valve solenoid.
Contains power and action indicator light.
To ensure that the system can be easily expanded.
Cable Specifications: Fire-retardant, Robot cable.
No. of connector poles: 4.
Cable connection direction: Straight.
No. of cable cores: 2.
Cable outer diameter: 6.0 mm dia.
Cable core cross-sectional area: 0.5 mm.
Cable length: 0.3 m.
AC: Model.
Minimum order: 10.
UL-listed: Yes.
Water- and Environment-resistive FA XW3B-P653-G11 OMRON.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
XW3B-P653-G11
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on XW3B-P653-G11 OMRON.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Rated voltage: 100 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 2.9 m3/min; 60 Hz, 3.1 m3/min.
Maximum static pressure: 50 Hz, 42 Pa; 60 Hz, 41 Pa.
Noise: 50 Hz, 47 dB; 60 Hz, 48 dB XW3B-P653-G11 OMRON.
Weight: Approx. 3380 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Control voltage: 100/110/120 VAC.
Reset: Manual.
Model: Inverse type.
SSolid-state Relay Provides Three Operating XW3B-P653-G11.
Functions in a Compact Package.
Prevents burnouts in 3-phase induction motors due to overcurrent,
open-phase, or reverse-phase.
LEDs indicate operation of the selected operating function. XW3B-P653-G11.
Wide setting ranges: current: 1 to 160 A; operating time: 1 to 40 s.
Protects the motor from reversing without starting it.
before using the K2CM.