Unit: CPU Units.
Name: Economy type (Expansion I/O Units cannot be connected).
No. of I/O points: 10.
LCD display: Yes.
Power supply voltage: 100 to 240 VAC.
Inputs: 6, 100 to 240 VAC.
Outputs: 4, Relays.
Buttons, calendar, and clock: Yes.
Analog input: NO.
Even Broader Applications with Increased.
Functionality and Higher Precision.
Increased functionality in a compact body (70 mm wide × 90 mm high).
buttons. (See note 1.).
switch functions.
I/O points. (See note 2.).
added to series.
Improved Weekly Timers (See note 1.).
max. Multiple-day operation and pulse output operation have,
been added.
100 to 240 VAC or 12 to 24 VDC.
Classification: Preset Counter.
Input signal system (Count & reset inputs): Contact, Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high), Up indicator.
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: No.
Control output: Contact (SPST-NO) ZEN-10C3AR-A-V2 OMRON.
Operating mode: Up counting.
Max.counting speed: 5 kcps (see note 1
ZEN-10C3AR-A-V2).
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter.
Power supply freely selectable within a range of 100 to 240 VAC ZEN-10C3AR-A-V2 OMRON.
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Type: H5CZ.
Time specifications: Timer Mode, A-2: Power ON Delay I,
b: Repeat cycle 1, E: Interval, Z: ON/OFF-duty-adjustable flicker,
Twin Timer Mode, toff: Flicker OFF Start 1, ton: Flicker ON Start 1 ZEN-10C3AR-A-V2 OMRON.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: 8-pin socket.
Inputs: None.
Outputs: Contact output (time-limit SPDT + instantaneous SPDT) Models with, instantaneous contact outputs.
Supply voltage: 12 to 24 VDC/24 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and innput circuits are isolated for safety and reliability ZEN-10C3AR-A-V2.
Set value limit function prevents unexpected operation of output devices.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer oor,
the load ZEN-10C3AR-A-V2.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection.