For temperature / humidity measurement.
Make your entire production environment visible.
Multi-point monitoring of environmental data and central control.
Sensor that can be connected: Thermo-Humidity Sensor Head (ZN-THS1__-S).
Display: LCD 7-segment 5-digit 2-step display,
auxiliary information indicator display.
Measurement interval: 10 s, 20 s, 30 s, 1 min, 2 min,
5 min, 10 min, 20 min, 30 min, 1 h.
Calculation function: Instantaneous value, maximum value,
minimum value, average value ZN-TH11-S OMRON.
Operating mode: Normal mode, sleep mode
ZN-TH11-S
Recording mode: Continue, ring.
Alarm signal output: Output to photocoupler (External power supply: 12 to 24 VDC,
Load current: Max. 45 mA) Alarm hold setting is possible.
Internal storage device: Internal memory: Approx. 8,500 data items.
External storage device: SD card (to save measured values and to save/read set, values),Recommended SD card: HMC-SD291 (manufactured by OMRON) ZN-TH11-S OMRON.
Power supply voltage: DC input: 24 VDC±10%, Battery: 2 AAA batteries.
Battery life: Approx. 1 year∗6 (sleep mode, measurement interval of 10 minutes, with 2 AAA nickel metal hydride batteries, with SD card not inserted).
Operating temperature range: 0 to 60°C.
Operating humidity range: 20 to 85% (no condensation) ZN-TH11-S OMRON.
Weight (packaged): Approx. 500 g.
Accessories: Instruction Sheet, Startup Guide CD-ROM∗7,
Alarm output connector∗8, DC cable (straight type).
Easy temperature and humidity control with an SD Card. Appearance: Sensor head: Anchored type.
Temperature: Measurement range, 0 to 60°C;
Measurement precision, ±0.3°C (at 25°C); Resolution, 0.1°C.
Relative humidity: Measurement range, 20 to 85%;
Measurement precision, ±2.5% (at 25°C, 10 to 85%); Resolution, 0.1%.
Weight (packaged): Approx. 300 g.
Accessories: Mounting screw (M3 x 8) x 1 Caps to secure cable,
(one for each, front and rear).
Easy temperature and humidity control with an SD Card. Rated primary current: 100 A.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stoppped power ZN-TH11-S. )
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settingss ZN-TH11-S.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.