LK166
Home >> Products >> OMRON >> Power/other peripheral devices >> Data recorder >> ZR-RX70A-CHRO | OMRON ZR-RX70A-CHRO Data Logger

ZR-RX70A-CHRO | OMRON ZR-RX70A-CHRO Data Logger

Brand: OMRON
Name: Data Logger
Model: ZR-RX70A-CHRO
Item: Data Logger.
Easy-to-use and Compact 10-Channel Logger,
with Internal 4 GB Flash Memory.

Rated voltage: 230 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 2.9 m3/min; 60 Hz, 3.1 m3/min.
Maximum static pressure: 50 Hz, 42 Pa; 60 Hz, 41 Pa.
Noise: 50 Hz, 47 dB; 60 Hz, 48 dB OMRON ZR-RX70A-CHRO.
Weight: Approx. 3380 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting ZR-RX70A-CHRO
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment OMRON ZR-RX70A-CHRO.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. SYSMAC PLC Units: CJ-series CPU Units, CS-series CPU Units,
Serial Communications Unit.
Cable length L: 2 m.
Host: Personal computer: IBM PC/AT or compatible.
Ideal Cables for between Programmable Controllers and Host Computers OMRON ZR-RX70A-CHRO. Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase) ZR-RX70A-CHRO OMRON.
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase ZR-RX70A-CHRO OMRON.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of opperation ZR-RX70A-CHRO.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions ZZR-RX70A-CHRO OMRON OMRON ZR-RX70A-CHRO. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.


...More relevant models >>>>