Power: 400kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode.
Equipped with standard power retrogradation function.
MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 22kw.
SLD converter rated current: 125A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on MITSUBISHI FR-HC2-H400K
FR-HC2-H400K
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units MITSUBISHI FR-HC2-H400K.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display. Power: 37kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost MITSUBISHI FR-HC2-H400K.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving. "MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V FR-HC2-H400K MITSUBISHI.
Power: 2.2kw.
SLD converter rated current: 8.3A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have.
Built in DC reactor FR-HC2-H400K MITSUBISHI.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption FR-HC2-H400K MITSUBISHI.
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of the iinverter
The status of the signal output, as well as the monitor output and so on, can be customized according to the requirements FR-HC2-H400K.
The control of each machine can be done separately by the frequency converter, and the controol of the dispersion is also carried out MITSUBISHI FR-HC2-H400K.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "