LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI A2ACPUP21-S4 Programming Manual (Common Instructions) PDF

MITSUBISHI A2ACPUP21-S4 Programming Manual (Common Instructions) PDF

Brand: MITSUBISHI
Product model: A2ACPUP21-S4
Name: Programmable Logic Controller
Sort: Programming Manual (Common Instructions)
File language: English
File size: 3.29MB
10BASE-T.
Q mode.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A2ACPUP21-S4 PDF A2ACPUP21-S4
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program A2ACPUP21-S4 PDF. A1ST60 analog timer module has 8 analog timers.
Each timer can be set between 0.1-600S,
Its accuracy plus or minus 2%.
Dial setting on the timing constant panel of the timer,
With a small screwdriver can be easily adjusted. Output points: 16 points A2ACPUP21-S4 PDF.
Voltage: DC24V/AC240V, 2A/1 point, 16A/ all points.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
All points of independence.
38 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor MITSUBISHI Programmming Manual A2ACPUP21-S4 Manual.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal MITSUBISHI Programming Manual .
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points MITSUBISHI Programming Manual .
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be knownn,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A2ACPUP21-S4 Manual A2ACPUP21-S4 Programming Manual .
Related products
MITSUBISHI
CPU unit
A2ACPU
MITSUBISHI CPU unit A2ACPU
Input and output points: 512 points. Input /
MITSUBISHI
CPU unit
A2ACPU-S1
MITSUBISHI CPU unit A2ACPU-S1
Input and output points: 1024 points. Input /
MITSUBISHI
CPU unit
A2ACPUR21
MITSUBISHI CPU unit A2ACPUR21
Input and output points: 512 points. Input /
MITSUBISHI
CPU unit
A2ACPUP21-S3
MITSUBISHI CPU unit A2ACPUP21-S3
Input and output points: 512 points. Input /