MITSUBISHI C70 Series Setup Manual PDF

Brand: MITSUBISHI
Product model: C70 Series
Name: CNC
Sort: Setup Manual
File language: English
File size: 21.65MB
Output type: relay output.
Output points: 4 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC30V/AC250V/2A C70 Series PDF.
External connection: 2 wire.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negative pole.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition C70 Series
Can be installed along the 6 direction. Input type: DC input, positive common end.
Input points: 16 points.
Input response time: 0.5ms below /1 C70 Series PDF. 5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 3 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. No introductionOutput type: transistor output, source.
Output points: 8 points C70 Series PDF.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC122V/DC24V/0 C70 Series Manual. 1A.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0.3~1.5MM square.
Terminal block is 2 piece structure MITSUBISHI Setup Manual.
An input module shared by the common terminal of the positive and negative.
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction. Output type: transistor output, drain type.
Output points: 4 points.
OFF leakage current: 0.1mA.
Output protection function: No MITSUBISHI Setup Manual.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 2 wire.
Spring clip terminal.
Do not need to re tighten, suitable for wire specifications for 0.3~1.5MM square.
Terminal block is 2 piece structure.
An input module shared by the common terminal of the positive and negative MITSUBISHI Setup Manual.
The 8 point of the output module is appended to the source type.
Can be installed along the 6 direction. Input type: DC input, positive public end / negative public end.
Input points: 4 points.
Enter the response time: 0.5ms/1.5ms the following.
Rated inputt voltage / current: DC24V/4mA C70 Series Setup Manual.
External connection: 2 wire.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negativve pole C70 Series Manual.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction.
Related products
MITSUBISHI
Old small A series main substrate
QA1S35B
MITSUBISHI Old small A series main substrate QA1S35B
5 slots requires 1 AnS series PLC power modu
MITSUBISHI
Old small A series main substrate
QA1S33B
MITSUBISHI Old small A series main substrate QA1S33B
3 slots requires 1 AnS series PLC power modu
MITSUBISHI
Old small A series expansion substrate
QA1S51B
MITSUBISHI Old small A series expansion substrate QA1S51B
1 slots no power supply used to install lar