Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI L Series Programming Manual (MELSAP-L) PDF

MITSUBISHI L Series Programming Manual (MELSAP-L) PDF

Brand: MITSUBISHI
Product model: L Series
Name: PLC
Sort: Programming Manual (MELSAP-L)
File language: English
File size: 3.16MB
Output points: 8 points.
Output form: no public side (all points independent).
Rated output voltage: AC100 ~ 240V.
Max load current: 1A/1 point.
Common way: no public side (all points of independence) L Series PDF.
Input / output occupied points: 16 points (I/O distribution: output 16 points).
External wiring connection: 18 point terminal.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system L Series
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged L Series PDF.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged.
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation.
4, the use of Modbus protocol, good general, can be very conveniennt and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible L Series PDF L Series Manual .
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability MITSUBISHI Programming Manual. Number of input channels: 2Ch.
Differential drive input.
Maximum count rate: pulse/s 500K.
Linear counter function.
Ring counter function.
Uniform output function.
Preset function.
Count invalid function.
Latch counter function.
Sampling counter function.
Periodic pulse counter function MITSUBISHI Programming Manual.
Flexibly applied to various applications
Combination of functions,
Easy to achieve speed measurement, long measuring function, the single pulse output, the ratio of the set / distribution output, PWM control, cam switch control, such as a wide range of control.
Single pulse.
To trigger the input as a starting point, with a minimum 25ns unit to adjust the ON/OFF time MITSUBISHI Programming Manual.
The action time deviation of ON/OFF is ns level, so it can achieve high precision control. L Series Programming Manual.
Velocity measurement and length measurement
In addition to the measurement of ON width and OFF width,
Can also achieve different sensor ON time difference and other conditions of the measurement.
The high precision measurement of the smallest 25ns unit can be realized L Series Manual .
Delayed output
The output time delay of each channel can be adjusted so that the error output can be realized.
Related products
MITSUBISHI
Servo motor without oil seal
HF-SE102B
MITSUBISHI Servo motor without oil seal HF-SE102B
Type: HF-SE servo motor, medium inertia power
MITSUBISHI
Servo motor without oil seal
HF-KE43
MITSUBISHI Servo motor without oil seal HF-KE43
Type: HF-KE servo motor, low inertia, low pow
MITSUBISHI
Servo motor without oil seal
HF-KE73
MITSUBISHI Servo motor without oil seal HF-KE73
Type: HF-KE servo motor, low inertia, low pow
MITSUBISHI
A mode Q series CPU
Q02CPU-A
MITSUBISHI A mode Q series CPU Q02CPU-A
Input / output points: 4096 points. Numer of