MITSUBISHI FR-A740-45K-C9 TECHNICAL MANUAL PDF

Brand: MITSUBISHI
Product model: FR-A740-45K-C9
Name: INVERTER
Sort: TECHNICAL MANUAL
File language: English
File size: 30.21MB
MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 450KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor FR-A740-45K-C9 PDF FR-A740-45K-C9
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor FR-A740-45K-C9 PDF FR-A740-45K-C9 Manual .
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity. Length: 65CM.
Function: connect GM-FX FR-A740-45K-C9 PDF.
Corresponding models: FX2N-10GM, FX2N-20GM. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 0.75kw.
SLD converter rated current: 7.7A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation MITSUBISHI TECHNICAL MANUAL.
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station.
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine MITSUBISHI TECHNICAL MANUAL.
No external PID controller is used to control the external machine, so the system cost can be reduced. Display: 7 segment digital display ++ icon display FR-A740-45K-C9 TECHNICAL MANUAL.
Can monitor, change the value of software components MITSUBISHI TECHNICAL MANUAL.
Can also be simple to operate, change the value.
Equipped with a button operation can be used (operator certification function)) and control through the PLC control function,
Can be used with the function expansion board FR-A740-45K-C9 Manual .
Can be installed directly to the FX3S, FX3SA, no wiring.
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-1.5K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-1.5K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-22K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-22K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-355K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-355K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l
MITSUBISHI
3 phase 400V converter
FR-A740-18.5K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-18.5K-CHT
MITSUBISHI inverter FR-A740 series. Voltage l