Max input / output points: 16 points.
Supply voltage: 100 - 240VAC.
Input points: 8 points.
Output points: 8 points.
Output type: silicon controlled.
Power consumption: 20W FR-E540-1.5K-CH PDF.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications FR-E540-1
FR-E540-1.5K-CH5K-CH PDF.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules FR-E540-1.5K-CH PDF.
TThe basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type) FR-E540-1.5K-CH Manual.
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable MITSUBISHI INSTRUCTION MANUAL.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit MITSUBISHI INSTRUCTION MANUAL.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate MITSUBISHI INSTRUCTION MANUAL.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, usiing a eight digit password to protect your program FR-E540-1.5K-CH INSTRUCTION MANUAL.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FR-E540-1.5K-CH Manual.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).