MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 2.2KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus FR-E5ND PDF.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy
FR-E5ND
Speed control method of fan and pump equipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the process of closure FR-E5ND PDF.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements. Max input / output points: 14 points FR-E5ND PDF.
Power supply voltage: DC24V.
Input points: 8 points.
Output points: 6 points.
Output type: relay.
Power consumption (W): 32.
Weight (kg):0.4.
Size (WxHxD) mm::90x90x75 FR-E5ND Manual.
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board MITSUBISHI INSTRUCTION MANUAL.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect.
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control MITSUBISHI INSTRUCTION MANUAL. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 5.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible MITSUBISHI INSTRUCTION MANUAL.
Transducer can be used to drive a single phase motor? Can single phase power supplly be used?
Basically can not be used FR-E5ND INSTRUCTION MANUAL. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-E5ND Manual.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft.