Power: 0.75kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity FR-E700 Series PDF.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor
FR-E700 Series)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Input and output points: 32 points.
Input points: 16 points FR-E700 Series PDF.
Output points: 16 points.
Output form: relay output.
Weight: 0.65kg.
Input signal voltage: DC24V.
FX2N series expansion unit
Expansion unit is an input and output expansion device with a built-in power supply.
As with the basic unit, the extension unit can be connected to a variety of input and output and special extension equipment FR-E700 Series PDF.
Can connect to FX3GA/FX3G, FX3GE and FX3U.
AC power model, the built-in maximum DC24V 250mA/460mA supply power.
Because all models of FX series are built in high speed counter,
So the high speed control can be realized by the simple procedure MITSUBISHI Instruction manual.
The input of the basic unit is built in the anti jitter filter,
One part as digital filter,
Sensitivity adjustment unit cann reach 1ms FR-E700 Series Manual .
Using high speed counter automatically adjusted to the minimum value.
Through the high cost of the built-in positioning function and the expansion function to increase the number of control axis MITSUBISHI Instruction manual.
Extended function expansion board and special adapter,
Data links and communication with external serial devices. Power: 560kw.
Voltage: 400V.
The power factor of the input power factor is up to 0.99 and above (100% load).
Can be connected to multiple inverters, to achieve a common DC bus mode MITSUBISHI Instruction manual.
Equipped with standard power retrogradation function. Power: 0.75kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling FR-E700 Series Instruction manual.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between thhe short circuit chip, in addition to connecting the DC reactor FR-E700 Series Manual .
The installation of thermal relay, to avoid overheating and burn the braking resistor.