Function extension board for RS-232C communication.
No DC24V consumption, do not take up input and output. Max input / output points: 10 points.
Supply voltage: 100 - 240VAC FX2N-48MT-DSS PDF.
Input points: 6 points.
Output points: 4 points.
Output type: relay.
Power consumption (W): 19.
Weight (kg):0.22.
Size (WxHxD) mm:60x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types
FX2N-48MT-DSS
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain FX2N-48MT-DSS PDF.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication FX2N-48MT-DSS PDF. Length: 1.5m.
Specification: FX round connector. Output points: 32 points.
Power supply: the basic unit to the expansion module to provide power.
Output form: transistor output (source).
Terminal type: connector type MITSUBISHI PROGRAMMING MANUAL II.
Weight: 0.2kg.
FX3GC, FX3UCC can be directly connected to the input and output expansion equipment, to achieve a compact expansion FX2N-48MT-DSS Manual.
Can choose 16 points, 32 points of the relay or transistor input and output models.
FX2NC-16E_-T-DS for terminal units can be disassembled models. Power: 110kw MITSUBISHI PROGRAMMING MANUAL II.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose MITSUBISHI PROGRAMMING MANUAL II. ) MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 2.2kw.
SLD converter rated current: 5.2A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumptiion FX2N-48MT-DSS PROGRAMMING MANUAL II.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control FX2N-48MT-DSS Manual.