RS-485 communication. Special communication adapter.Input / output type: transistor output (source).
Output points: 8 points.
DC5V internal consumption current: 75mA FX2NC-64MT-DSS PDF.
DC24V internal consumption current: 75mA.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points
FX2NC-64MT-DSS MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V FX2NC-64MT-DSS PDF.
Frequency converter capacity: 2.2KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) FX2NC-64MT-DSS PDF.
Starting with power frequency power ssupply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical FX2NC-64MT-DSS Manual.
The inverter drive can be smoothly start (start time longer).
The starting current is 1 MITSUBISHI HARDWARE MANUAL. 2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load. Input and output points: 24 points.
Power supply: AC100-240V MITSUBISHI HARDWARE MANUAL.
Input points: 14 points.
Output points: 10 points.
Output form: transistor output (drain).
Power consumption: 32W.
Weight: 0.55KG.
Outline dimension: 90x90x86mm.
FX3GE on the performance of the FX3GA increased analog input / output and Ethernet communication and other built-in features.
Applicable to a wide variety of applications MITSUBISHI HARDWARE MANUAL.
Basic unit: 24/40 point.
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost PLC.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 pooints FX2NC-64MT-DSS HARDWARE MANUAL.
A versatile PLC.
Built in CPU, power supply, input and output, analog input and output, Ethernet port, can be used immediately after the purchase.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Applicatioon instruction: 0 FX2NC-64MT-DSS Manual. 5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function.