MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 37kw.
SLD converter rated current: 187A.
Structure and function: Standard model FX2NC-32MT-DSS PDF.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection
FX2NC-32MT-DSS
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment) FX2NC-32MT-DSS PDF.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps FX2NC-32MT-DSS PDF. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 0.75kw.
SLD converter rated current: 7.7A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models MITSUBISHI HARDWARE MANUAL.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed coontrol loop terminal station FX2NC-32MT-DSS Manual.
Built in 2 PID arithmetic MITSUBISHI HARDWARE MANUAL. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine.
No external PID controller is used to control the external machine, so the system cost can be reduced. Max input / output points: 14 points.
Power supply voltage: 24VDC.
Input points: 8 points MITSUBISHI HARDWARE MANUAL.
Output points: 6 points.
Output type: relay.
Power consumption (W): 6.5.
Weight (kg):0.22.
Size (WxHxD) mm:60x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through thhe installation of BD series PLC board, can achieve RS232, RS485, RS422 communication FX2NC-32MT-DSS HARDWARE MANUAL.
All equipment is digital input and output point.
The total I/O points are not more than 30 points, and the input points are less than 16, thhe output points are less than 14 FX2NC-32MT-DSS Manual.
Its MT series of PLC can drive 2 way servo or stepper, commonly used in the control system for a simple manipulator.