IE Field CC-Link intelligent equipment station.
Transmission speed: 1Gbps.
Remote input / output: 2048 points.
Remote register: 1024 words.
RAS function L02SCPU-P PDF.
End cap.
Play the role of IE CC-Link field network remote station
Can be installed in the IE CC-Link field network host module L series of a variety of I/O module, intelligent function module.
Can be used as the remote station of IE CC-Link field network,
The flexible configuration of I/O module and intelligent function module is realized,
Reduce device wiring, save space
L02SCPU-P
Management of abnormal information through the RAS function
An error occurred in the remote station,
After the error record is saved to the IE CC-Link field network host module''s latch area,
Instantaneous notification to the master station via the network L02SCPU-P PDF.
Even if the power of the system is cut off, the error record in the locked area is still retained,
So it is easy to determine the location of the problem, to maximize the reduction of downtime L02SCPU-P PDF. Thermocouple input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current supppression L02SCPU-P Manual.
Heating function at the same time MITSUBISHI Programming Manual.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time MITSUBISHI Programming Manual. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function MITSUBISHI Programming Manual.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs.
To achieve high stability temperature control
Standard control / heating, cooling control.
The devicce used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling L02SCPU-P Programming Manual.
According to the object device can choose any one of the following control method.
Standard controol (heating or cooling) L02SCPU-P Manual.
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control).