Brand: MITSUBISHI
Product model: L06CPU-CM
Name: PLC
Sort: Programming Manual (Application Functions)
File language: English
File size: 5.25MB
"Universal output function: leakage type.
Program capacity: 60K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Control mode: stored procedure repeated operation L06CPU-CM PDF.
Input / output points: 4096 points.
End cap.
CPU built-in functions can be easily set through programming tools.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool L06CPU-CM
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement L06CPU-CM PDF.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated ".
High precision PWM control of the highest 200kHz.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s L06CPU-CM PDF L06CPU-CM Manual.
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators. "Output channel number: 4ch.
Output voltage: DC - 10 ~ 10V MITSUBISHI Programming Manual.
Output current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm MITSUBISHI Programming Manual.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve stable measurement MITSUBISHI Programming Manual.
High speed, smooth continuoous analog output L06CPU-CM Programming Manual.
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulatted according to the set conversion period L06CPU-CM Manual.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.
Related products
MITSUBISHI
cpu module
L06CPU-CM
MITSUBISHI cpu module L06CPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L02SCPU-CM
MITSUBISHI cpu module L02SCPU-CM
"Universal output function: leakage type. Pro
MITSUBISHI
cpu module
L06CPU-P
MITSUBISHI cpu module L06CPU-P
"Universal output function: source type. Prog
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type. Pro