Temperature measurement resistor input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control L26CPU-PBT PDF.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function
L26CPU-PBT
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion L26CPU-PBT PDF.
No idle running, with energy saving effect, can reduce operating costs.
Can make multi loop to reach the target value (SV) of the same time.
By setting the simultaneous heating of the channel group, up to 2 groups of units, respectively, at the same time warming.
It is very effective to use the control object that does not want to heat up to the time of arrival error L26CPU-PBT PDF.
Applicaable to a variety of systems L26CPU-PBT Manual.
Sampling period switching function.
Sampling period can be selected from 250ms/4ch and 500ms/4ch.
Equipped with temperature input mode.
The temperature control module can be used as a temperature input module MITSUBISHI User's Manual.
By setting the switch, you can easily change the input mode. Cable length: 3.0m.
Weight: 0.45kg.
Definition 1: conductor by one or a plurality of mutually insulated and insulating protective layer made of,
A conductor of electricity or information from one place to another MITSUBISHI User's Manual.
Definition 2: usually by a few or several groups (each with at least two wires) cable rope twisted the similar,
Each group of wires are insulated from each other, and are often twisted around a center,
The entire outer bread has a highly insulated cover.
The cable has the characteristics of internal power and external insulation MITSUBISHI User's Manual. CC-Link/LT master station.
Transmission speed: 2.5Mbps.
Remote input / output: 1024 points.
16 point mode.
In the cabinet, the device can also respond to high speed.
CC-Link/LT link scan time to reach tthe highest 1 L26CPU-PBT User's Manual. 2ms (2.5Mbps) at 64 stations,
Excellent response performance is achieved.
Can be selected according to the transmission distance 2.5Mbps, 625kbps, 156kbps.
Comfortable environment without network awareness.
Paraameter settings that do not require any trouble L26CPU-PBT Manual.
Moreover, the transmission speed only through the master module to set, can easily use the remote I/O.