Input: 2 channels.
Input: thermocouple / micro voltage / voltage / current.
Conversion speed (input):25ms/2 channel.
Sampling period: 25ms/2 channel.
Output: DC4~20mA Q00UJCPU-SET PDF.
Conversion speed (output):25ms/2 channel.
18 point terminal station.
With 5 kinds of PID control mode.
Loop control module suitable for fast response object control, such as temperature control, flow control, etc..
The loop control module has a PID control format and a sampling period of 25ms that is proportional to the speed,
Support high precision, high resolution Thermocouple Input, micro voltage input, voltage input, current input and current output Q00UJCPU-SET PDF
Q00UJCPU-SET
The most suitable for high speed lift and temperature control and pressure control, flow control and other requirements of the application of high speed response.
Can be connected with JIS, IEC, NBS, ASTM standard thermocouple.
Through the small voltage, voltage, current input sensor, can be measured in a variety of input range of analog Q00UJCPU-SET PDF.
Provides the program control function, can according to the specific requirements of the time automatically change the target value (SV) and PID constant [proportional band (P), integration time (I), differential time (D)],
And cascade control function, allowing channel 1 as the main station, channel 2 for the control from the station MITSUBISHI Programming Manual. "10BASE2.
Ethernet interface module capable of selecting the most suitable system and object device.
Support 100BASE-TX, can speed up the transmission speed. (QJ71E71-100)
Data communication can be performed between programmable controller CPU using special instructions MITSUBISHI Programming Manual.
Can use the HTTP protocol, through the Web browser on the PC access to the soft element off the programmable controller Q00UJCPU-SET Manual.
PC (Web) on the use of the communication program library and sample screen can be obtained by download services MITSUBISHI Programming Manual.
Can connect a number of programming tools to improve the efficiency of debugging.
Make use of e-mail function, through the mail server to send e-mail (ASCII format) and attachments (binary, ASCII and CSV format).
The KeepAlive function can be used to perform the existence of the object equipment inspection, and keep the connection in the open state.
This can be used to ensure connectivity and to quickly find errors.
Optimal network matching for application purposes and applications,
Seamless communication between different hierarchical systems.
Enhancing the ability of information communication through network.
This is also a major task in the field of automation.
Network environment provided by Q series
Is truly open & seamless.
Including based on universal ethernet,
Achieve easy management of the environment "IE Control CC-Link" controller network,
As well as in its management to achieve a high-speed, high-capacity transmission of the "IE Field CC-Link" field network Q00UJCPU-SET Programming Manual.
Also including Japan''s first, to achieve the world standard,
And get the SEMI certification of the field network "CC-Link",
And inherited the design concept of the provincial distributioon network CC-Link/LT" Q00UJCPU-SET Manual.
And support sensor networks "AnyWire",
To enrich the lineup flexibility to integrate the various layers of automation network. "