LK166
Home >> Products >> MITSUBISHI >> R series PLC >> CPU module >> R16SFCPU-SET MITSUBISHI Safety CPU

R16SFCPU-SET MITSUBISHI Safety CPU

Brand: MITSUBISHI
Name: Safety CPU
Model: R16SFCPU-SET
Safety grade (SIL): SIL 3 (IEC 61508).
Performance level (PL): e PL (13849-1 EN/ISO).
Operation control mode: stored procedures repeated operation.
Program capacity: 160K (security program: 40K).
Program memory: 640K.
Soft element / tag memory: 1710K.
Data memory: 10M.
Integrate security functions into the control system.
Can be used in the previous iQ-R MELSEC series module as a general control purposes,
Use on the same substrate, it can be used to construct a hybrid system with general control and safety control.
Moreover, IE Field CC-Link network can be integrated with general communication and secure communication,
Ethernet cable can also be used in secure communication,
No need to use a dedicated cable, etc..
In line with the international safety standards for the safety of CPU can be controlled at the same time the general system and safety system.
Available through IE Field CC-Link network,
Connect the safety switch and safety light curtain system used to secure CPU,
System for the construction of a general control and safety control system.
In addition, through the use of intuitive engineering software Works3 GX,
Focus on general control and safety control programming.

Analog input channel number: 8CH.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0.1%.
Ambient temperature 0 ~ 55 degrees C:-.
Temperature coefficient: positive and negative 35ppm/.
Common
Conversion speed: 10ms.
Insulation between channels: isolation transformer insulation R16SFCPU-SET MITSUBISHI.
Absolute maximum input: positive and negative 15V, 30mA.
External wiring connection mode: 40 pin connector R16SFCPU-SET
Voltage input
The analog input voltage: DC - 10 - 10V.
Digital output value: 32000 ~ 32000.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
Analog input module for the external analog signal into the interface of the programmable controller.
Can choose the channel between the insulation, voltage input, current input, voltage / current mixed input, thermocouple input, temperature resistance (RTD) input for a variety of purposes, such as modules R16SFCPU-SET MITSUBISHI.
Filter high frequency interference.
Analog input module has been equipped with a first order lag filter.
The analog input signal with high frequency interference component can be obtained by using the first order lag filter R16SFCPU-SET MITSUBISHI.
Parameters can be set through the filter time constant, no program can be easy to use.
Execute event driven program through alarm output
Strengthen the implementation of the interrupt function according to the alarm output flag, easy to carry out preventive maintenance.
The measured value and the change rate of the analog input signal exceed the upper and lower limits of the set,
Regardless of the procedure of the scan time, can be executed interrupt handling, quickly respond to abnormal conditions. 1Gbps, master / local station.
IE Field CC-Link network is a kind of field network based on Gigabit Ethernet,
Integrated control of the controller, I/O control, safety control, motion control, can carry out a full range of control.
According to the production line, equipment, equipment layout, the star, linear and ring topology of flexible wiring.
Building a flexible network
Star topology
Star connection is carried out among the modules by using switching hubs.
When using star topology, you can easily add from the station.
Linear topology
Between the modules to carry out a linear connection.
Distribution cost can be reduced.
Ring topology
Ring connection in between each module.
Part of the anomaly occurs from the station, can be through the ring back function,
Use only normal station to ccontinue data link R16SFCPU-SET.
Support IE Field CC-Link network synchronous communication function
According to the synchronization period specified by the master station, the control period of the slave station is synchronized by the IE Field CC--Link network R16SFCPU-SET.
According to this, the action time of the station can be synchronized with other slave stations which are connected on the same network.


...More relevant models >>>>