PCI bus.
Support Japanese, English OS.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station).
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module Q00UJCPU-SET PDF.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps
Q00UJCPU-SET
Improve the communication response, significantly shorten the cycle time.
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time Q00UJCPU-SET PDF.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume norrmal operation Q00UJCPU-SET PDF Q00UJCPU-SET Manual.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings MITSUBISHI Programming Manual.
Only need to set up the transmission speed in the master module, you can use the remote I/O.MES interface module.
Need MX MESInterface software and CF card.
Easily connect production equipment and information system.
Through the excellent database sharing function, greatly reduce the cost of information MITSUBISHI Programming Manual.
By direct connection, the connection process of the enterprise system database (such as MES) is simplified.
Module configuration is simple, without any programming.
The data can be monitored in the module side, when a user defined trigger condition occurs,
Will be read in the form of SQL text and send the specified data to the MES MITSUBISHI Programming Manual.
The network load can be reduced compared with the previous scheme which is based on the gateway PC to obtain / monitor the data Q00UJCPU-SET Programming Manual.
Receive information from the MES, perform pre stored SQL tasks.
In addition, the production instructions from the MES are also receeived,
The production information can be downloaded from the database, and the modification of the formula information can be conveniently carried out Q00UJCPU-SET Manual.