LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q01UCPU Reference Manual (Communication Protocal) PDF

MITSUBISHI Q01UCPU Reference Manual (Communication Protocal) PDF

Brand: MITSUBISHI
Product model: Q01UCPU
Name: PLC
Sort: Reference Manual (Communication Protocal)
File language: English
File size: 7.14MB
Board module installation location: QS series power module mounting slot.
Suitable substrate module: QS034B.
Input power: AC100~120V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system Q01UCPU PDF.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards Q01UCPU
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures Q01UCPU PDF.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immmediately shut down Q01UCPU PDF Q01UCPU Manual. SRAM memory card.
RAM capacity: 128KB. 4 axis, differential drive output type.
Control unit: pulse MITSUBISHI Reference Manual.
Location data: 10 data / axis.
Maximum pulse output: 4Mpps.
40 pin connector.
Differential output.
Ideal solution for simple multi axis positioning.
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle.
To speed up the speed of positioning control to start processing MITSUBISHI Reference Manual.
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control MITSUBISHI Reference Manual.
(the command pulse of the open collector positioning module is highest 200kpps.)
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory cardd Q01UCPU Reference Manual.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage ccard in advance Q01UCPU Manual.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Related products
MITSUBISHI
CPU unit
A2CCPU
MITSUBISHI CPU unit A2CCPU
Input and output points: 512 points. Input /
MITSUBISHI
With Ethernet CPU
Q50UDEHCPU
MITSUBISHI With Ethernet CPU Q50UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
Motion CPU module
Q172HCPU
MITSUBISHI Motion CPU module Q172HCPU
Control axis: maximum 8 axes. Teaching operat
MITSUBISHI
CPU unit
A2USCPU
MITSUBISHI CPU unit A2USCPU
Input and output points: 512 points. Input /