LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q03UDCPU Programming Manual (MELSAP-L) PDF

MITSUBISHI Q03UDCPU Programming Manual (MELSAP-L) PDF

Brand: MITSUBISHI
Product model: Q03UDCPU
Name: CPU
Sort: Programming Manual (MELSAP-L)
File language: English
File size: 1.76MB
Input: 4 channels.
Platinum resistance (Pt100; JPt100).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station Q03UDCPU PDF.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q03UDCPU
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q03UDCPU PDF.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q03UDCPU PDF.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected MITSUBISHI Programming Manual. Q6TA32 special tool.8 slots; requires 1 AnS series PLC power modules;
Used to install large AnS series PLC module.
Base plate of AnS series PLC.
QA1S series PLC 8 slot main substrate.
AnS series of modules can be installed MITSUBISHI Programming Manual. 8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT input module Q03UDCPU Manual.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc MITSUBISHI Programming Manual. .
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored.
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost.
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will sudddenly change Q03UDCPU Programming Manual.
By detecting the transient peak current at this time, the fault of the equipment can be diagnosed.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value)) Q03UDCPU Manual.
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored.
Related products
MITSUBISHI
General high speed CPU
Q03UDVCPU
MITSUBISHI General high speed CPU Q03UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
Motion CPU module
Q172DCPU
MITSUBISHI Motion CPU module Q172DCPU
Control axis: maximum 8 axes. Peripheral I/F:
MITSUBISHI
Motion CPU module
Q173DCPU
MITSUBISHI Motion CPU module Q173DCPU
Control axis: maximum 32 axes. Manual pulse g
MITSUBISHI
With Ethernet CPU
Q03UDECPU
MITSUBISHI With Ethernet CPU Q03UDECPU
Input / output points: 4096 points. Numer of