LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q06UDVCPU Programming Manual (Common Instructions 1/2) PDF

MITSUBISHI Q06UDVCPU Programming Manual (Common Instructions 1/2) PDF

Brand: MITSUBISHI
Product model: Q06UDVCPU
Name: CPU
Sort: Programming Manual (Common Instructions 1/2)
File language: English
File size: 56.79MB
SRAM memory card.
RAM capacity: 128KB. "2 axes, SSCNET III type.
2 axis linear interpolation.
2 axis arc interpolation.
Control unit: mm, inch, degree, pulse Q06UDVCPU PDF.
Location data: 600 data / axis.
40 pin connector.
Through the SSCNET III cable connection to save wiring, the distance between the station up to 50m.
Absolute position system for determining the origin position is supported by the return data set operation Q06UDVCPU
In addition, the limit switch of the upper limit, the lower limit switch and the near point block signal input can be directly connected to the servo amplifier,
Thus greatly reducing the wiring requirements Q06UDVCPU PDF.
Easy to achieve high speed, high precision positioning control.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, path switching control, constant speed control etc Q06UDVCPU PDF. .
In addition, can use the "Configurator-QP GX" and other sofftware,
Easy to set, monitor and debug Q06UDVCPU Manual. "Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly MITSUBISHI Programming Manual .
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file MITSUBISHI Programming Manual . Multimode fiber optic cable.
Double circuit.
Controller network (control station / common station).
With external power supply function.
Decentralized control of large scale controller,
IE CC-Link controller network module connected with various field network MITSUBISHI Programming Manual .
Effectively using Ethernet cable and connector on the market, can reduce the cost.
The performance of the cycle data updaate is improved Q06UDVCPU Programming Manual .
The transmission delay time is shortened, and the synchronous waiting time of the application can be shortened.
On the same network to achieve the 256KB network shared memory (cycle data).
No need to distinguish thee network can handle large capacity data Q06UDVCPU Manual.
QJ71GP21S-SX, CC-Link can be used as the control station of IE QJ71GP21-SX controller network, common station.
Related products
MITSUBISHI
General high speed CPU
Q03UDVCPU
MITSUBISHI General high speed CPU Q03UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
General high speed CPU
Q06UDVCPU
MITSUBISHI General high speed CPU Q06UDVCPU
Input / output points: 4096 points. Input / o
MITSUBISHI
CPU unit
A3VCPU
MITSUBISHI CPU unit A3VCPU
Multiple CPU units for A3VTS multiplex system
MITSUBISHI
General high speed CPU
Q04UDVCPU
MITSUBISHI General high speed CPU Q04UDVCPU
Input / output points: 4096 points. Input / o