Master station.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2 Q172HCPU PDF. 5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O Q172HCPU
QJ61CL12 can be used as the main station of CC-Link/LT.4 channel.
Input: DCO~20mA DC-10~10V.
Output (resolution): 0~32000; -32000~32000; 0~64000; -64000~64000.
Conversion speed: 10ms/4 channel Q172HCPU PDF.
18 point terminal station.
Isolation beetween channels Q172HCPU Manual.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller Q172HCPU PDF.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier MITSUBISHI Strctured Programming Manual.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module MITSUBISHI Strctured Programming Manual. Master station module supporting AnyWireASLINK system.
Connecting sensor and programmable controller.
Free configuration of sensors, control of 512 points of tthe input and output Q172HCPU Strctured Programming Manual.
The AnyWireASLINK transmission line (2 lines) can be used for communication to supply power for the sensor, and the sensor can also be conveniently added MITSUBISHI Strctured Programming Manual.
Can through thee project software GXWorks2 batch management sensor shedding detection and from the station module settings, etc Q172HCPU Manual. ,
Substantial savings in time and cost.
Related products
MITSUBISHI
With Ethernet CPU
Q04UDEHCPU
MITSUBISHI With Ethernet CPU Q04UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
Process CPU
Q25PHCPU
MITSUBISHI Process CPU Q25PHCPU
Program capacity: 252 K step. Input / output
MITSUBISHI
Process CPU
Q02PHCPU
MITSUBISHI Process CPU Q02PHCPU
Program capacity: 28 K step. Input / output p