8 channel.
Input: DC-10~10mA; 0~20mA.
Output (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; 0~16000; -16000~16000.
Conversion speed: 10ms/ channel Q173CPUN-T PDF.
40 pin connector.
Isolation between channels.
The possibility of expanding control with intelligent function.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark
Q173CPUN-T
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output Q173CPUN-T PDF.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input module Q173CPUN-T PDF.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules. Q173CPUN-T Manual.
Using the inter channel isolation analog module.PCI bus.
Support Japanese, English OS.
SI/QSI/H-PCF/ broadband H-PCF cable.
Dual loop controller network (control station / common station).
With external power supply function MITSUBISHI Programming Manual .
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings MITSUBISHI Programming Manual .
Only need to set up the transmission speed in the master module, you can use the remote I/O.
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station MITSUBISHI Programming Manual .
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized.
The distance betwween stations, the length of the total cable length, strong anti-interference Q173CPUN-T Programming Manual .
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network.
Twisted pair bus system Q173CPUN-T Manual. ..... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low.