LK166
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI Q173CPUN-T Programming Manual (SFC) PDF

MITSUBISHI Q173CPUN-T Programming Manual (SFC) PDF

Brand: MITSUBISHI
Product model: Q173CPUN-T
Name: CPU
Sort: Programming Manual (SFC)
File language: English
File size: 2.11MB
8 slots.
The main substrate needs to be equipped with CPU and power supply.
Support for high speed communication between multi CPU.
Requires 1 power modules Q173CPUN-T PDF.
Used to install Q series modules.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module Q173CPUN-T
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields Q173CPUN-T PDF.
Can also be used in combination with the CPU module to achieve appropriate control.5 slots; requires 1 AnS series PLC power modules;
Used to install large AnS series PLC module.
Base plate of AnS series PLC.
QA1S series PLC 5 slot main substrate.
AnS series of modules can be installed Q173CPUN-T PDF. Input: 8 channels.
30kpps/10kpps/1kpps/100pps/50pps/10pps/1pps/0.1pps.
Counter input signal: DC5/12-24V.
The module is suitable for the measurement of the number of input pulses, such as speed, speed, instantaneous flow rate and so on,
As wwell as the quantity, the length, the cumulative flow and so on the measurement MITSUBISHI Programming Manual Q173CPUN-T Manual.
Input pulse values are updated every 10ms.
The number of pulses (sampling pulse number), which can be accumulated and processed by the moving average, is updated according to the counting period. The input and output module installation number: 4 MITSUBISHI Programming Manual .
Could extend the connection: not to extend the connection.
Application module: QS series module.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system MITSUBISHI Programming Manual .
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outsidee the standard control procedures Q173CPUN-T Programming Manual .
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q173CPUN-T Manual. "
Related products
MITSUBISHI
Motion CPU module
Q173CPUN-T
MITSUBISHI Motion CPU module Q173CPUN-T
Control axis: maximum 32 axes. Teaching runni
MITSUBISHI
Sports CPU module (old model)
Q173CPU
MITSUBISHI Sports CPU module (old model) Q173CPU
Control axis: maximum 8 axes. Greater flexii
MITSUBISHI
Motion CPU module
Q173CPUN
MITSUBISHI Motion CPU module Q173CPUN
Control axis: maximum 32 axes. Compact size a
MITSUBISHI
Motion CPU module
Q172CPUN-T
MITSUBISHI Motion CPU module Q172CPUN-T
Control axis: maximum 8 axes. Teaching runnin