SRAM+E2PROM memory card.
RAM capacity: 128KB.
E2PROM capacity: 128KB. Master / local station sharing.
Corresponding Ver2 CC-Link.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of Q20UDHCPU PDF.
Even if the information reaches saturation, it will not affect the link scan time
Q20UDHCPU
The QJ61BT11N module supports CC-Link version 1 and version 2, which can be used as a local station or master station module.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) Q20UDHCPU PDF. Control axis: maximum 32 axes.
Teaching operation function: No.
To stop the speed control function at the specified location.
The servo motor can rotate at a predetermined speed,
After starting the specified location to stop the instruction,
Can be set in advance to stop the location Q20UDHCPU PDF.
You can change the speed by changging the value of the options at the time of the operation,
You can also change the acceleration / deceleration time Q20UDHCPU Manual.
Phase compensation function MITSUBISHI Programming Manual.
The mixed function of virtual mode and real mode.
Smooth clutch linear acceleration / deceleration function.Output points: 4 points (select the source type + drain type), 2 points (select the source type + source).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V MITSUBISHI Programming Manual.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards MITSUBISHI Programming Manual.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outsiide the standard control procedures Q20UDHCPU Programming Manual.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q20UDHCPU Manual.