Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly QS001CPU PDF.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic
QS001CPU
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file QS001CPU PDF. "1ch RS-232.
1ch RS-422/485.
QJ71C24N (-R2) through the RS-232 serial communication,
Programming and monitoring of programmable controllers using programming tools.
QJ71C24N (-R2) with the function of the modem corresponding to the public telephone line,
Can be used to initialize the modem, and the connection of the object device processing,
Communication with a remote device, a programming tool, a modem, and a public telephone line QS001CPU PDF.
Using remote password,
Can be prevented by QJ71C24N (-R2) function of the modem Q series programmable controller for illegal access.
Serial communication module capable of collecting and changing data of programmable controller, monitoring and managing, measuring data collection and so on MITSUBISHI Programming Manual.
Can achieve the highest speed of 230.4kbps, the maximum of 960 words (MC protocol communications) of the high speed and large capacity communications.
Can use MC protocol, through the external devices (PC, monitors, etc MITSUBISHI Programming Manual. ) to implement the data read / write programmable controller.
By selecting a non sequential protocol and use sequential program for communication control, the programmable controlller and the external device (barcode reader and measurement equipment),
Communication with local protocols using external devices MITSUBISHI Programming Manual QS001CPU Manual. "Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machhine,
The temperature regulating module has the function of preventing overheating and preventing over cooling QS001CPU Programming Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode QS001CPU Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.