Large tactile buttons and uniform lighting to create a general space.
Backlight brings a uniform, elegant and pleasant lighting.
Large tactile buttons are easier to touch CJ2M-CPU12 PDF.
Drive rod mechanism to keep the direction of the parallel button, even if the pressure on the side of the.
Damping mechanism to ensure high impact resistance.
A slim body with a thickness of 14.6 mm. Product name: N@@-type CPU Units with 30 I/O Points
CJ2M-CPU12
Specifications: Power Supply, 24 VDC; Inputs, 8; Outputs, 6;
Output type: Transistor (sourcing).
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): -- CJ2M-CPU12 PDF.
Current consumption: 5 V, 0.22A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CJ2M-CPU12 PDF. C500-IM I/O Unit INPUT MODULE 16POINT 24VAC/DC C500-IM211(3G2A5-IM211)) CJ2M-CPU12 Manual.
AC/DC12-24V 10mA。Product name: CJ2M CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2, 560 points/40 Units(3 ExpansionRacks max OMRON PROGRAMMING MANUAL. );Programcapacity,
5K steps;Data memorycapacity, 64K words,
(DM: 32K words, EM: 32K words ×1 bank);
LD nstruction execution time, 0. 04 μs;
EtherNet/IP function: --;
Option board slot: --.
Current consumption (A): 5V, 0 OMRON PROGRAMMING MANUAL. 7(See note. );24V, --.
Standards: UC1, N, L, CE.
CJ2M for basic machine automation.
The CJ2M Series is ideal for packaging and general.
machine automation needs. Connectivity is assured.
thanks to the built-in USB port and the choice of.
Ethernet and RS-232C/422/485 interfaces on the CPU OMRON PROGRAMMING MANUAL. Specification: 32 input points.Specification: 16 input points, 16 output points.Name: e-CON Connectors.
Specifications: Outputs; 32 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CJ2M-CPU12 PROGRAMMING MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CJ2M-CPU12 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.