Power supply: AC power supply.
Output method: Transistor output source type.
Inputs points: 6 points.
Outputs points: 4 points.Unit classification: CJ1 Special I/O Units CP1L-EM40DR-D PDF.
Product name: Position Control Units,
(High Speed type).
Specifications; Control method/Control,
output interface: Pulse-train open-collector,
output with Pulse Counter Function;
Number of control axes : 2 axes
CP1L-EM40DR-D
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.27A; 24V, --.
Standards: UC1, CE.
Motion Control Capabilities with Unit,
Synchronization and Even Higher Speed.
Models are available with 2 or 4 axes,
and open-collector or line-driver outputs CP1L-EM40DR-D PDF.
The CJ1W-NC214/NC414 have open-collector outputs,
and the CJ1W-NC234/NC434 have line-driver outputs.
Control 2 or 4 Axes High-speed, high-resolution,
position control is possible for servomotors ,
and pulse motors, and even linear motors,
and direct drive motors CP1L-EM40DR-D PDF. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Uniit CP1L-EM40DR-D Manual.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs OMRON REFERENCE MANUAL.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON REFERENCE MANUAL.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them OMRON REFERENCE MANUAL.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CP1L-EM40DR-D REFERENCE MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1L-EM40DR-D Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.