Name: e-CON Connectors.
Specifications: Outputs; 16 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CS1G-CPU44-V1 PDF.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction
CS1G-CPU44-V1
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CS1G-CPU44-V1 PDF. Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 64 outputs;
Maximum switching capacity, 12 to 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, MIL connector CS1G-CPU44-V1 PDF.
No. of words allocated: 4 words.
Current consumption: 5V, 0.17A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perrform ON/OFF,
control for external devices OMRON INSTRUCTIONS REFERENCE MANUAL CS1G-CPU44-V1 Manual.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput.
Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 32 inputs/outputs;
External connection, Removable terminal block.
No OMRON INSTRUCTIONS REFERENCE MANUAL. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications OMRON INSTRUCTIONS REFERENCE MANUAL.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
Name: Clamp Terminal Blocks.
Specifications: Outputs; 8 outputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost cann be reduced CS1G-CPU44-V1 INSTRUCTIONS REFERENCE MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1G-CPU44-V1 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.