Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action) D4JL-2NFA-C7-23 PDF.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available
D4JL-2NFA-C7-23)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads D4JL-2NFA-C7-23 PDF.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certiffied standards: UL, EN (TÜV), and CCC D4JL-2NFA-C7-23 Manual. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 3NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4JL-2NFA-C7-23 PDF.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads OMRON INSTRUCTION sheet.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Type: 1-conduit.
Mounting direction: Front-side mounting.
Conduit size: G1/2.
2NC (Slow-action).
The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts OMRON INSTRUCTION sheet.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL and CSA standards.
The Switch contact is opeened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened OMRON INSTRUCTION sheet D4JL-2NFA-C7-23 INSTRUCTION sheet. The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operationn prevented by special Operation Key D4JL-2NFA-C7-23 Manual.
Wide temperature range specifications: −40 to 80°C.
Degree of protection of the switch box: IP67 (EN60947-5-1).