Ratings: 0.1 A.
Actuator: Hinge roller lever.
Terminals: Molded lead wires (300 mm).
Contact form: SPDT.
Sealed Miniature Basic.
Switch Conforms to IP67 D4N-2B72 PDF.
(Excluding the terminals on terminal models).
Use of epoxy resin assures stable sealing, making.
this switch ideal for places subject to water spray.
or excessive dust.
V-series internal mechanism assures high.
precision and durability
D4N-2B72 The mounting is the,
same as of the V models.
Ideal for automobiles, agricultural machines,
large-scale home appliances, and industrial,
equipment, which require high environmental resistance. Release key type: Special release key D4N-2B72 PDF.
Indicator: Green.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+3NC.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns D4N-2B72 PDF.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas D4N-2B72 Manual.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas OMRON INSTRUCTION sheet.
IP67 degree of protection. Type of drive rod: one-way action roller type (vertical motion).
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC) OMRON INSTRUCTION sheet.
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used OMRON INSTRUCTION sheet. Receptacle box: G 1/2 Conduit.
Indicator: With neon lamp indicator (AC).
Actuator: Roller lever *1, High-sensitivity.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide stanndard operating temperature range:
-40°C to +100°C (standard type) D4N-2B72 INSTRUCTION sheet.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4N-2B72 Manual.
Approved by UL, CSA, and CCC (Chinese standard).