Brand: OMRON
Product model: D4SL-N2HFA-DN
Name: guard lock safety-door switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.57MB
Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO (Slow-action).
A Series of Pull-reset Models Now D4SL-N2HFA-DN PDF.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement D4SL-N2HFA-DN
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC D4SL-N2HFA-DN PDF. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: SJT(O) cable *3.
Actuator: Center roller lever.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4SL-N2HFA-DN PDF. )
Sealing characteristics that meet IEC IP67 degree of protection.
Triiple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material OMRON INSTRUCTION sheet D4SL-N2HFA-DN Manual.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation OMRON INSTRUCTION sheet. )
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: Plunger.
Conduit openings: M20.
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts OMRON INSTRUCTION sheet.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion D4SL-N2HFA-DN INSTRUCTION sheet.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4SL-N2HFA-DN Manual.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.