LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON D4SL-N2PFG-DN datasheet PDF

OMRON D4SL-N2PFG-DN datasheet PDF

Brand: OMRON
Product model: D4SL-N2PFG-DN
Name: Guard Lock Safety-door Switch/D4SL-N-mounting Slide Key
Sort: PDF datasheet
File language: English
File size: 6.12MB
Type: 1-conduit.
Mounting direction: Front-side mounting.
Conduit size: G1/2.
2NC (Slow-action).
The Special Operation Key Activates a Direct.
Opening Mechanism to Open the Contacts.
and Shut Off Control Circuits when Protective.
Doors Are Opened on Machine Tools or Other.
Equipment.
Conforms to EN (TÜV) standards corresponding to the CE marking D4SL-N2PFG-DN PDF.
Certified by UL and CSA standards D4SL-N2PFG-DN
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened. The EN-certified.
direct opening mechanism is indicated by on the Switch.
Malfunctions and false operation prevented by special Operation Key.
Wide temperature range specifications: −40 to 80°C D4SL-N2PFG-DN PDF.
Degree of protection of the switch box: IP67 (EN60947-5-1). Actuator: Roller lever (metal lever, resin roller).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available D4SL-N2PFG-DN PDF. )
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Head material: Plastic*1.
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 3NC+1NC/1NO.
Conduit opening: M20.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectablle Operation Key insertion direction and,
adjustable mounting ensure installation flexibility D4SL-N2PFG-DN datasheet.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for eithher standard loads or microloads D4SL-N2PFG-DN datasheet.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available.