Actuator: Roller lever (resin lever, bearing roller).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches D4SL-N2VFA-N PDF.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
D4SL-N2VFA-N
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4SL-N2VFA-NN PDF D4SL-N2VFA-N Manual.
Certified standards: UL, EN (TÜV), and CCC. Action force (OF):0.49N (low load action type).
Switch timing: no short circuit type.
Drive rod: needle shaped button type.
Super small check switch with push button action type
Super small (6 x 8 x width high depth 4 D4SL-N2VFA-N PDF. 2mm), light weight (about 0.3 grams), long stroke 3mm.
Short circuit and non short circuit time built-in sliding device capable of selecting switch.
Widely used in small household electrical appliances, audio equipment, office equipment, communication equipment, etc..
Actuator: Adjustable roller lever OMRON INSTRUCTION sheet.
Conduit openings: M20.
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts OMRON INSTRUCTION sheet.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Equipped with a mechaniism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion OMRON INSTRUCTION sheet D4SL-N2VFA-N INSTRUCTION sheet.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4SL-N2VFA-N Manual.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.