Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Side plunger, Vertical roller.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength D4SL-N3NFG-D PDF.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type)
D4SL-N3NFG-D
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations D4SL-N3NFG-D PDF.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)
The drive rod: rod type Shibai leaf.
Contact specifications: 1a.
Rating: general load with 1A.
For the automobile, industrial vehicles, mechanical testing of the anti immersion type (in line with IP67)
Use M4 screw to achieve a little installation D4SL-N3NFG-D PDF.
Using a strong fixed leaf swing rod which can adapt to the harsh environment.
Full consideration of environmental protection, the installation of the wire also lead to lead free. Classification: Standard models OMRON INSTRUCTION sheet.
Auxiliaary monitoring output: Photocoupler outputs *1 D4SL-N3NFG-D Manual.
Cable length: 2 m.
Supports ISO 13849-1 (PLe/Safety Category 4).
Can be used on higher risk level applications,
by connecting to Safety Controllers.
Supports a wide range of applications in combination with,
Safety Controller G9SP or Non-contact Door Switch,
Controller G9SX-NS@ OMRON INSTRUCTION sheet.
Up to 30 units can be connected.
Ideal for middle to large scale device applications.
Contributes to shortening the time it takes to find,
the cause of failure by the switch''s LED display patterns.
Photocoupler monitor output allows connection to,
a general-purpose PLC (NPN type) OMRON INSTRUCTION sheet.
Compatibility with the D40A allows standardization of machine design.
Compact Non-contact Door Switch can be mounted from both sides. Actuator: Roller lever (metal lever, metal roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact formss D4SL-N3NFG-D INSTRUCTION sheet.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used witth both standard loads and microloads D4SL-N3NFG-D Manual.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.